Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Int J Comput Assist Radiol Surg ; 19(3): 591-599, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37523011

RESUMO

PURPOSE: The aim of the study was to assess the deviation between clinical implant axes (CIA) determined by a surgeon during preoperative planning and reconstructed tooth axes (RTA) of missing teeth which were automatically computed by a previously introduced anatomical SSM. METHODS: For this purpose all available planning datasets of single-implant cases of our clinic, which were planned with coDiagnostix Version 9.9 between 2018 and 2021, were collected for retrospective investigation. Informed consent was obtained. First, the intraoral scans of implant patients were annotated and subsequently analyzed using the SSM. The RTA, computed by the SSM, was then projected into the preoperative planning dataset. The amount and direction of spatial deviation between RTA and CIA were then measured. RESULTS: Thirty-five patients were implemented. The mean distance between the occlusal entry point of anterior and posterior implants and the RTA was 0.99 mm ± 0.78 mm and 1.19 mm ± 0.55, respectively. The mean angular deviation between the CIA of anterior and posterior implants and the RTA was 12.4° ± 3.85° and 5.27° ± 2.97° respectively. The deviations in anterior implant cases were systematic and could be corrected by computing a modified RTA (mRTA) with decreased deviations (0.99 mm ± 0.84 and 4.62° ± 1.95°). The safety distances of implants set along the (m)RTA to neighboring teeth were maintained in 30 of 35 cases. CONCLUSION: The RTA estimated by the SSM revealed to be a viable implant axis for most of the posterior implant cases. As there are natural differences between the anatomical tooth axis and a desirable implant axis, modifications were necessary to correct the deviations which occurred in anterior implant cases. However, the presented approach is not applicable for clinical use and always requires manual optimization by the planning surgeon.


Assuntos
Implantes Dentários , Cirurgia Assistida por Computador , Dente , Humanos , Tomografia Computadorizada de Feixe Cônico , Estudos Retrospectivos , Próteses e Implantes , Desenho Assistido por Computador , Imageamento Tridimensional
2.
J Clin Med ; 12(24)2023 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-38137614

RESUMO

X-linked hypophosphatemia is a rare, hereditary disorder that significant influences teeth and alveolar bone. The first clinical sign leading to the diagnosis of X-linked hypophosphatemia is often dental impairment with dental abscesses and dentin mineralization defects. Genetic analysis helped find the responsible gene and therefore opened up new ways of therapeutically managing X-linked hypophosphatemia. The human monoclonal antibody Burosumab represents a milestone in the targeted therapy of this hereditary disease by directly addressing its pathophysiology. Targeted therapy has been shown to improve skeletal impairment, pain, and phosphate metabolism. However, the influence of this new therapy on dental impairment has only been addressed in a few recent studies with varying results. Therefore, in this review, we aim to summarize the dental phenotype and analyze the different treatment modalities with a focus on dental impairment.

3.
Dentomaxillofac Radiol ; 52(6): 20230059, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37427585

RESUMO

OBJECTIVES: This study evaluated the accuracy of deep neural patchworks (DNPs), a deep learning-based segmentation framework, for automated identification of 60 cephalometric landmarks (bone-, soft tissue- and tooth-landmarks) on CT scans. The aim was to determine whether DNP could be used for routine three-dimensional cephalometric analysis in diagnostics and treatment planning in orthognathic surgery and orthodontics. METHODS: Full skull CT scans of 30 adult patients (18 female, 12 male, mean age 35.6 years) were randomly divided into a training and test data set (each n = 15). Clinician A annotated 60 landmarks in all 30 CT scans. Clinician B annotated 60 landmarks in the test data set only. The DNP was trained using spherical segmentations of the adjacent tissue for each landmark. Automated landmark predictions in the separate test data set were created by calculating the center of mass of the predictions. The accuracy of the method was evaluated by comparing these annotations to the manual annotations. RESULTS: The DNP was successfully trained to identify all 60 landmarks. The mean error of our method was 1.94 mm (SD 1.45 mm) compared to a mean error of 1.32 mm (SD 1.08 mm) for manual annotations. The minimum error was found for landmarks ANS 1.11 mm, SN 1.2 mm, and CP_R 1.25 mm. CONCLUSION: The DNP-algorithm was able to accurately identify cephalometric landmarks with mean errors <2 mm. This method could improve the workflow of cephalometric analysis in orthodontics and orthognathic surgery. Low training requirements while still accomplishing high precision make this method particularly promising for clinical use.


Assuntos
Pontos de Referência Anatômicos , Crânio , Adulto , Humanos , Masculino , Feminino , Reprodutibilidade dos Testes , Cefalometria/métodos , Crânio/diagnóstico por imagem , Algoritmos
4.
BMC Surg ; 23(1): 4, 2023 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-36624485

RESUMO

BACKGROUND: Computer Assisted Design and Computer Assisted Manufacturing (CAD/CAM) have revolutionized oncologic surgery of the head and neck. A multitude of benefits of this technique has been described, but there are only few reports of donor site comorbidity following CAD/CAM surgery. METHODS: This study investigated comorbidity of the hip following deep circumflex iliac artery (DCIA) graft raising using CAD/CAM techniques. A cross-sectional examination was performed to determine range of motion, muscle strength and nerve disturbances. Furthermore, correlations between graft volume and skin incision length with postoperative donor site morbidity were assessed using Spearman's rank correlation, linear regression and analysis of variance (ANOVA). RESULTS: Fifteen patients with a mean graft volume of 21.2 ± 5.7 cm3 and a mean incision length of 228.0 ± 30.0 mm were included. Patients reported of noticeable physical limitations in daily life activities (12.3 ± 11.9 weeks) and athletic activities (38.4 ± 40.0 weeks in mean) following surgery. Graft volume significantly correlated with the duration of the use of walking aids (R = 0.57; p = 0.033) and impairment in daily life activities (R = 0.65; p = 0.012). The length of the scar of the donor-site showed a statistically significant association with postoperative iliohypogastric nerve deficits (F = 4.4, p = 0.037). Patients with anaesthaesia of a peripheral cutaneous nerve had a larger mean scar length (280 ± 30.0 mm) than subjects with hypaesthesia (245 ± 10.1 mm) or no complaints (216 ± 27.7 mm). CONCLUSIONS: Despite sophisticated planning options in modern CAD/CAM surgery, comorbidity of the donor site following  iliac graft harvesting is still a problem. This study is the first to investigate comorbidity after DCIA graft raising in a patient group treated exclusively with CAD/CAM techniques. The results indicate that a minimal invasive approach in terms of small graft volumes and small skin incisions could help to reduce postoperative symptomatology. Trial registration Retrospectively registered at the German Clinical Trials Register (DRKS-ID: DRKS00029066); registration date: 23/05/2022.


Assuntos
Cicatriz , Artéria Ilíaca , Humanos , Cicatriz/epidemiologia , Cicatriz/etiologia , Computadores , Estudos Transversais , Artéria Ilíaca/cirurgia , Mandíbula/cirurgia , Morbidade
5.
Micromachines (Basel) ; 13(10)2022 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-36295956

RESUMO

Nonunion is one of the most dreaded complications after operative treatment of mandible fractures or after mandible reconstruction using vascularized and non-vascularized bone grafts. Often diagnosis is made at advanced stage of disease when pain or complications occur. Devices that monitor fracture healing and bone regeneration continuously are therefore urgently needed in the craniomaxillofacial area. One promising approach is the strain measurement of plates. An advanced prototype of an implantable strain measurement device was tested after fixation to a locking mandible reconstruction plate in multiple compression experiments to investigate the potential functionality of strain measurement in the mandibular region. Compression experiments show that strain measurement devices work well under experimental conditions in the mandibular angle and detect plate deformation in a reliable way. For monitoring in the mandibular body, the device used in its current configuration was not suitable. Implant strain measurement of reconstruction plates is a promising methodical approach for permanent monitoring of bone regeneration and fracture healing in the mandible. The method helps to avoid or detect complications at an early point in time after operative treatment.

6.
Bone Rep ; 17: 101611, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36120645

RESUMO

Purpose: Morphological variability of the skull is an important consideration for cranioplasty and implant design. Differences in morphology of the skull based on the ethnicity are known. In a previous study we could show the accuracy and benefits of virtual reconstructions based on a statistical shape model (SSM) for neurocranial defects. As the SSM is trained on European data, the question arises how well this model fares when dealing with patients with a different ethnic background. In this study we aim to evaluate the accuracy and applicability of our proposed method when deploying a cranial SSM generated from European data to estimate missing parts of the neurocranium in a Chinese population. Methods: We used the same data and methods as in our previous study and compared the outcomes when applied to Chinese individuals. A large unilateral defect on the right side and a bilateral defect were created. The outer surface of the cranial table was reconstructed from CT scans, meshed with triangular elements, and registered to a template. Principal component analysis together with Thin Plate Spines (TPS) deformation was applied to quantify modes of variation. The mesh to mesh distances between the original defects´ surfaces and the reconstructed surface were computed. Results: Comparing the Chinese test group with the European control group, regarding the entire defect the analysis shows no significant difference for unilateral defects (test vs. control group/0.46 mm ± vs. 0.44 mm). Reconstruction of bilateral defects exhibited only in slightly higher prediction errors than those of unilateral defects (0.49 mm ± vs. 0.45 mm). Conclusion: The proposed method shows a high accuracy that seems to be ethnical independent - with low error margins for virtual skull reconstruction and implant design.Clinical relevance: Metallic objects may severely impact image quality in several CBCT devices.

7.
Int J Comput Assist Radiol Surg ; 17(10): 1957-1968, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35902422

RESUMO

PURPOSE: Modern virtual implant planning is a time-consuming procedure, requiring a careful assessment of prosthetic and anatomical factors within a three-dimensional dataset. In order to facilitate the planning process and provide additional information, this study examines a statistical shape model (SSM) to compute the course of dental roots based on a surface scan. MATERIAL AND METHODS: Plaster models of orthognathic patients were scanned and superimposed with three-dimensional data of a cone-beam computer tomography (CBCT). Based on the open-source software "R", including the packages Morpho, mesheR, Rvcg and RvtkStatismo, an SSM was generated to estimate the tooth axes. The accuracy of the calculated tooth axes was determined using a leave-one-out cross-validation. The deviation of tooth axis prediction in terms of angle or horizontal shift is described with mean and standard deviation. The planning dataset of an implant surgery patient was additionally analyzed using the SSM. RESULTS: 71 datasets were included in this study. The mean angle between the estimated tooth-axis and the actual tooth-axis was 7.5 ± 4.3° in the upper jaw and 6.7 ± 3.8° in the lower jaw. The horizontal deviation between the tooth axis and estimated axis was 1.3 ± 0.8 mm close to the cementoenamel junction, and 0.7 ± 0.5 mm in the apical third of the root. Results for models with one missing tooth did not differ significantly. In the clinical dataset, the SSM could give a reasonable aid for implant positioning. CONCLUSIONS: With the presented SSM, the approximate course of dental roots can be predicted based on a surface scan. There was no difference in predicting the tooth axis of existent or missing teeth. In clinical context, the estimation of tooth axes of missing teeth could serve as a reference for implant positioning. However, a higher number of training data must be achieved to obtain increasing accuracy.


Assuntos
Implantes Dentários , Cirurgia Assistida por Computador , Desenho Assistido por Computador , Tomografia Computadorizada de Feixe Cônico/métodos , Estudos de Viabilidade , Humanos , Imageamento Tridimensional , Mandíbula , Maxila , Cirurgia Assistida por Computador/métodos
8.
Int J Comput Assist Radiol Surg ; 17(11): 2093-2101, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35665881

RESUMO

PURPOSE: Computer-assisted techniques play an important role in craniomaxillofacial surgery. As segmentation of three-dimensional medical imaging represents a cornerstone for these procedures, the present study was aiming at investigating a deep learning approach for automated segmentation of head CT scans. METHODS: The deep learning approach of this study was based on the patchwork toolbox, using a multiscale stack of 3D convolutional neural networks. The images were split into nested patches using a fixed 3D matrix size with decreasing physical size in a pyramid format of four scale depths. Manual segmentation of 18 craniomaxillofacial structures was performed in 20 CT scans, of which 15 were used for the training of the deep learning network and five were used for validation of the results of automated segmentation. Segmentation accuracy was evaluated by Dice similarity coefficient (DSC), surface DSC, 95% Hausdorff distance (95HD) and average symmetric surface distance (ASSD). RESULTS: Mean for DSC was 0.81 ± 0.13 (range: 0.61 [mental foramen] - 0.98 [mandible]). Mean Surface DSC was 0.94 ± 0.06 (range: 0.87 [mental foramen] - 0.99 [mandible]), with values > 0.9 for all structures but the mental foramen. Mean 95HD was 1.93 ± 2.05 mm (range: 1.00 [mandible] - 4.12 mm [maxillary sinus]) and for ASSD, a mean of 0.42 ± 0.44 mm (range: 0.09 [mandible] - 1.19 mm [mental foramen]) was found, with values < 1 mm for all structures but the mental foramen. CONCLUSION: In this study, high accuracy of automated segmentation of a variety of craniomaxillofacial structures could be demonstrated, suggesting this approach to be suitable for the incorporation into a computer-assisted craniomaxillofacial surgery workflow. The small amount of training data required and the flexibility of an open source-based network architecture enable a broad variety of clinical and research applications.


Assuntos
Processamento de Imagem Assistida por Computador , Redes Neurais de Computação , Computadores , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Tomografia Computadorizada por Raios X
9.
J Clin Med ; 11(9)2022 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-35566508

RESUMO

Adequate soft-tissue dimensions have been shown to be crucial for the long-term success of dental implants. To date, there is evidence that placement of dental implants should only be conducted in an area covered with attached gingiva. Modern implant planning software does not visualize soft-tissue dimensions. This study aims to calculate the course of the mucogingival borderline (MG-BL) using statistical shape models (SSM). Visualization of the MG-BL allows the practitioner to consider the soft tissue supply during implant planning. To deploy an SSM of the MG-BL, healthy individuals were examined and the intra-oral anatomy was captured using an intra-oral scanner (IOS). The empirical anatomical data was superimposed and analyzed by principal component analysis. Using a Leave-One-Out Cross Validation (LOOCV), the prediction of the SSM was compared with the original anatomy extracted from IOS. The median error for MG-BL reconstruction was 1.06 mm (0.49-2.15 mm) and 0.81 mm (0.38-1.54 mm) for the maxilla and mandible, respectively. While this method forgoes any technical work or additional patient examination, it represents an effective and digital method for the depiction of soft-tissue dimensions. To achieve clinical applicability, a higher number of datasets has to be implemented in the SSM.

10.
Int J Comput Dent ; 25(4): 349-359, 2022 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-35072424

RESUMO

PURPOSE: Creating wax-ups of missing teeth for backward planning in implant surgery is a complex and time-consuming process. To facilitate implant-planning procedures, the automatic generation of a virtual wax-up would be useful. In the present study, the reconstruction of missing teeth in partially edentulous patients was performed automatically using newly developed software. The accuracy was investigated in order to test its clinical applicability. MATERIALS AND METHODS: This study presents a new method for creating an automatic virtual wax-up, which could serve as a basic tool in modern implant-planning procedures. First, a statistical shape model (SSM) based on 76 maxillary and mandibular arch scans from dentally healthy individuals was generated. Then, artificially generated tooth gaps were reconstructed. The accuracy of the workflow was evaluated on a separate testing sample of 10 individuals with artificially created tooth gaps given as a median deviation, in millimeters. Scans of three clinical cases with partial edentulism were equally reconstructed using the SSM and compared with the final prosthodontic work. RESULTS: The reconstruction of the artificial tooth gaps could be performed with the following median reconstruction accuracy: gap 21 with 0.15 mm; gap 27 with 0.20 mm; gap 34 with 0.22 mm: gap 36 with 0.22 mm; gaps 12 to 22 with 0.22 mm; gaps 34 to 36 with 0.22 mm. A scenario for an almost edentulous mandible with all teeth missing except teeth 33 and 43 could be reconstructed with a median reconstruction accuracy of 0.37 mm. The median tooth gap deviation of the SSM-based reconstruction in clinical cases differed from the final inserted prosthodontic teeth by 0.49 to 0.86 mm in median. CONCLUSION: A first feasibility of creating virtual wax-ups using an SSM could be shown. Artificially generated tooth gaps could be reconstructed close to the original with the proposed workflow. In the clinical cases, the SSM proposes an anatomical reconstruction, which does not yet consider prosthodontic aspects. To obtain clinical use, contact with antagonist teeth must be considered and more training data must be implemented. However, the presented method offers a fast and viable way for the approximate placement of missing crowns. This could be used in a digital planning workflow when implant position must be determined. (Int J Comput Dent 2022;25(4):349-0; doi: 10.3290/j.ijcd.b2599407).


Assuntos
Implantes Dentários , Boca Edêntula , Humanos , Prostodontia , Modelos Estatísticos , Coroas
12.
J Pers Med ; 13(1)2022 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-36675756

RESUMO

BACKGROUND: Xenogeneic bone grafts, when compared to autologous grafts, are supposed to provide structural benefits without donor site morbidity. To date, there have been divergent results in the use of xenogeneic grafts in foot surgery, primarily in pediatric patient cohorts. The present study examines the incorporation and maintenance of the achieved correction using autologous and xenogeneic bone grafts in adult patients with a six-month follow-up period. MATERIAL/METHODS: In this retrospective study, 31 adult patients (43 feet in total) treated in our clinic by a lateral calcaneus-lengthening osteotomy, according to Evans, between 01/2006 and 12/2020 were included. The patients were assigned to study groups according to the use of xenogeneic or autologous bone grafts. The osseous incorporation following the criteria of Worth et al., correction maintenance by measuring the talo-navicular coverage angle (TNCA), the talo-first metatarsal angle (TFMA), the calcaneal pitch angle (PCA) and necessary revisions six months after surgery were extracted from the medical files retrospectively. Furthermore, the medical files were screened for the relevant comorbidities, nicotine abuse, BMI, sex and age. RESULTS: In total, 27 autogenous (iliac crest) and 16 xenogeneic bone grafts of bovine origin were used. The evaluation of the radiographs at follow-up demonstrated that there was a mean incorporation rate of 96.3% for the autologous grafts and 57% for the patients treated with xenogeneic grafts (p = 0.002). Compared to the autologous group, xenogeneic grafts did not increase the loss of hindfoot alignment in the postoperative course, regardless of being incorporated or not. ΔTNCA, ΔTFMA and ΔPCA displayed no significant differences in both groups (p = 0.45, p = 0.42 and p = 0.10). CONCLUSION: Despite a significantly lower incorporation rate, the use of xenogeneic grafts was not accompanied with a greater risk of hindfoot alignment loss in the first six months after surgery. Early revision after a postoperative course of six months should not be motivated solely by the radiographic picture of incomplete osseous integration.

13.
Arch Orthop Trauma Surg ; 142(11): 3035-3043, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33885961

RESUMO

INTRODUCTION: Currently there is no consensus how hindfoot alignment (HA) should be assessed in CBCT scans. The aim of this study is to investigate how the reliability is affected by the anatomical structures chosen for the measurement. MATERIALS AND METHODS: Datasets consisting of a Saltzman View (SV) and a CBCT of the same foot were acquired prospectively and independently assessed by five raters regarding HA. In SVs the HA was estimated as follows: transversal shift between tibial shaft axis and heel contact point (1); angle between tibial shaft axis and a tangent at the medial (2) or lateral (3) calcaneal wall. In CBCT the HA was estimated as follows: transversal shift between the centre of the talus and the heel contact point (4); angle between a perpendicular line and a tangent at the medial (5) or lateral (6) calcaneal wall; angle between the distal tibial surface and a tangent at the medial calcaneal wall (7). Intraclass correlation coefficients (ICC) were calculated to assess inter-rater reliability. A linear regression was performed to compare the different measurement regarding their correlation. RESULTS: 32 patients were included in the study. The ICCs for the measurements 1-7 were as follows: (1) 0.924 [95% CI 0.876-0.959] (2) 0.533 [95% CI 0.377-0.692], (3) 0.553 [95% CI 0.399-0.708], (4) 0.930 [95% CI 0.866-0.962], (5) 0.00 [95% CI - 0.111 to 0.096], (6) 0.00 [95% CI - 0.103 to 0.111], (7) 0.152 [95% CI 0.027-0.330]. A linear regression between measurement 1 and 4 showed a correlation of 0.272 (p = 0.036). CONCLUSIONS: It could be shown that reliability of measuring HA depends on the investigated anatomical structure. Placing a tangent along the calcaneus (2, 3, 5, 6, 7) was shown to be unreliable, whereas determining the weight-bearing heel point (1, 4) appeared to be a reliable approach. The correlation of the measurement workflows is significant (p = 0.036), but too weak (0.272) to be used clinically.


Assuntos
Tomografia Computadorizada de Feixe Cônico , , Pé/diagnóstico por imagem , Humanos , Radiografia , Reprodutibilidade dos Testes , Suporte de Carga , Raios X
14.
Laryngoscope ; 131(11): E2764-E2769, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34142721

RESUMO

OBJECTIVES/HYPOTHESIS: The prevalence of tympanostomy tube surgery (TTS) in patients with a cleft deformity was investigated, in relation to cleft width and cleft type. STUDY DESIGN: Retrospective review of medical health records. METHODS: Retrospective review of medical health records. Seventy-eight patients with non-syndromic cleft deformity of the palate and/or alveolus and lip between 2003 and 2017 were investigated. All available medical documents were analyzed. The study group was divided into subgroups: 1) patients with isolated cleft palate (CP) and patients with a cleft palate with cleft lip and alveolus (CLP). 2) According to Veau's classification (I-IV), further subgroups were defined. Cleft width was measured using plaster cast models. RESULTS: TTS was performed in 55% of the patients (n = 43). Considering Veau's classification, TTS was conducted as follows: Veau I 65.2% (n = 15/23), Veau II 55.0% (n = 11/20), Veau III 47.6% (n = 10/21), and Veau IV 50.0% (n = 7/14). Cleft classifications, maxillary arch width, and absolute/relative cleft width had no statistical impact on TTS occurrence. Although no significant correlation could be found, patients in our study group with CP (Veau I and II) underwent TTS more often (60.5%, n = 26/43) than patients with CPL (Veau III and IV; 48.6%, n = 17/35) during a three-year follow-up. CONCLUSION: None of the cleft characteristics examined had a significant impact on the proportion of patients who received TTS. Nevertheless, patients with lower Veau classification and CP received tympanostomy tubes more often. Therefore, otolaryngologists and pediatricians treating children with cleft palate should maintain a high level of suspicion for chronic middle ear effusion, even in patients with small clefts. LEVEL OF EVIDENCE: 3 Laryngoscope, 131:E2764-E2769, 2021.


Assuntos
Encéfalo/anormalidades , Fenda Labial/complicações , Fissura Palatina/complicações , Ventilação da Orelha Média/estatística & dados numéricos , Otite Média com Derrame/cirurgia , Encéfalo/patologia , Estudos de Casos e Controles , Moldes Cirúrgicos/normas , Fenda Labial/classificação , Fenda Labial/diagnóstico , Fenda Labial/patologia , Fenda Labial/cirurgia , Fissura Palatina/classificação , Fissura Palatina/diagnóstico , Fissura Palatina/patologia , Fissura Palatina/cirurgia , Arco Dental/anatomia & histologia , Feminino , Seguimentos , Perda Auditiva/diagnóstico , Perda Auditiva/etiologia , Humanos , Lactente , Masculino , Maxila/anatomia & histologia , Ventilação da Orelha Média/métodos , Otite Média com Derrame/complicações , Otite Média com Derrame/diagnóstico , Otorrinolaringologistas , Pediatras , Prevalência , Estudos Retrospectivos
15.
J Clin Pediatr Dent ; 45(3): 204-207, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-34192752

RESUMO

OBJECTIVE: To investigate the effect of lip closure on reduction of cleft palates when no pre-surgical infant orthopedics (PSIO) are used. STUDY DESIGN: Retrospective patient chart-review in our department for Cranio-Maxillofacial Surgery at the University Medical Centre Freiburg, Germany. 19 patients at the age of 5.9 ± 2.1 months with surgical treatment of uni- (UCLP), or bilateral cleft lip and palate (BCLP) without any use of PSIO were included. RESULTS: Early soft tissue correction of the lip leads to an effective reduction of the maxillary arch without any use of PSIO. The presented conventional and digital measurements appeared to be reliable. A successful reduction of the cleft width (UCLP = 3.88 ± 2.42mm, BCLP = 7.33 ± 5.00mm), the width of the alveolar arch (1.91 ± 1.36mm) and the sagittal depth of the alveolar arch (3.07 ± 2.71 mm) could be achieved with the presented workflow. CONCLUSIONS: Cleft reduction was obtainable without PSIO when lip closure after Tennison-Randall was performed.


Assuntos
Fenda Labial , Fissura Palatina , Ortopedia , Fenda Labial/cirurgia , Fissura Palatina/cirurgia , Arco Dental , Humanos , Lactente , Estudos Retrospectivos
16.
J Oral Maxillofac Surg ; 79(7): 1570-1579, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33675703

RESUMO

PURPOSE: There is no consensus on the impact of red blood cell (RBC) transfusion on patients with oral squamous cell carcinoma (OSCC). The purpose of this study was to investigate the association between RBC transfusions and overall survival (OS) and tumor-free survival (TFS) after operative treatment of OSCC. METHODS: In this retrospective cohort study, all patients treated with primary surgery between 2003 and 2017 because of OSCC were chart reviewed. The occurrence and amount of RBC transfusions (0; 1-3; >3 units) was correlated with OS and TFS by Kaplan-Meier survival and Cox regression analyses. Demographic, clinical, and pathological parameters were also evaluated in order to identify confounding factors. RESULTS: Of 420 patients (243 [57.9%] male) with a mean age of 62.6 years, 67 (16.0%) received RBC transfusion. There were statistically significant (P < .01) differences in 5-year OS respectively TFS in transfused patients for the Kaplan-Meier survival analysis (0 units = 70.6%; [95% confidence interval {CI}: 65.0-75.4%] respectively 63.2% [95% CI: 57.4-68.4%], 1-3 units = 47.2% [95% CI: 29.4-63.1%] respectively 40.6% [95% CI: 24.6-55.95%] and >3 units = 48.9% [95% CI: 20.9-72.1%] respectively 30.5% [95% CI: 8.9-55.8%]). After multivariate adjustments for demographic, clinical, and pathological parameters, RBC transfusion could not be sustained as a significant prognostic factor in OS respectively TFS (1-3 units: hazard ratio = 1.5 [95% CI: 0.7-3.2] respectively 1.3 [95% CI: 0.7-2.6]; >3 units: hazard ratio = 1.2 [95% CI: 0.5 - 3.0] respectively 1.1 [95% CI: 0.5-2.4]). CONCLUSIONS: Although RBC transfusion was not identified as a significant prognostic parameter in multivariate analysis, a clear trend for shorter OS and TFS for transfused patients in univariate and Kaplan-Meier survival analysis could be shown.


Assuntos
Carcinoma de Células Escamosas , Neoplasias de Cabeça e Pescoço , Neoplasias Bucais , Carcinoma de Células Escamosas/cirurgia , Transfusão de Eritrócitos , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Bucais/cirurgia , Estudos Retrospectivos , Carcinoma de Células Escamosas de Cabeça e Pescoço
17.
Cancers (Basel) ; 14(1)2021 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-35008301

RESUMO

There is no consensus on the effect of red blood cell (RBC) transfusions on patients with oral squamous cell carcinoma (OSCC). The aim of this study was to investigate the association between RBC administration and the occurrence of distant metastases (M+) after surgical treatment of OSCC. All medical records of patients who underwent primary surgery for OSCC in our department (2003-2019) were analyzed retrospectively (n = 609). Chi and Cox regression models were used to analyze the influence of transfusion on the development of M+, and survival rates. Kaplan-Meier curves were used for graphical presentation. A multitude of patient-specific factors showed a statistical impact in univariate analysis (transfusion, age, gender, diabetes, pT, pN, L, V, Pn, G, UICC, adjuvant therapy, free microvascular transplant, preoperative hemoglobin level). Transfusion status and pN stage were the only variables that showed a significant correlation to M+ in the multivariate Cox model. The hazard ratios for the occurrence of M+ were 2.42 for RBC transfusions and 2.99 for pN+. Administration of RBC transfusions was identified as a significant prognostic parameter for the occurrence of distant metastases after surgical treatment of OSCC. Hence, the administration of RBC transfusions should be considered carefully in the perioperative management.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...